Model | E2F-X1R5E[] | E2F-X2E[] | E2F-X5E[] | E2F-X10E[] | |
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) | ||||
Standard sensing object | Iron, 8 × 8 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response frequency *1 | E/F Models: 2 kHz, | E/F Models: 1.5 kHz, | E/F Models: 600 Hz, | E/F Models: 400 Hz, | |
Power supply voltage | E/FModels: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||||
Current consumption | E/FModels: 17 mA max. | ||||
Leakage current | Y Models: 1.7 mA max. at 200 VAC (Refer to Engineering Data on Data Sheet.) | ||||
Control | Load current | E/FModels: 200 mA max. | E/FModels: 200 mA max. | ||
Residual voltage | E/FModels: 2 V max. (Load current: 200 mA, Cable length: 2 m) | ||||
Indicators | E1 Models: Detection indicator (red), E2/F1/F2 Models: Operation indicator (red) | ||||
Operation mode | E1/F1/Y1 Models: NO | ||||
Protection circuits | E/F Models: Reverse polarity protection, Load short-circuit protection, Surge suppressor; Y Models: None | ||||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | E/F Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | E/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | IEC 60529 IP68, in-house standards: oil-resistant *2 | ||||
Connection method | Pre-wired Models (Standard cable length: 2 m) | ||||
Weight (packed state) | Approx. 40 g | Approx. 50 g | Approx. 130 g | Approx. 170 g | |
Materials | Case | Polyarylate resin | |||
Sensing surface | |||||
Clamping nuts | Polyacetal | ||||
Accessories | Instruction manual |
Tên sản phẩm | Cảm biến tiệm cận omron E2F |
Xuất xứ | - |
Bảo hành | - |
Chi tiết | - |