Sản phẩm

Cảm biến tiệm cận omron E2EM

Liên hệ để mua hàngGỌI NGAY 0904466176

 

Size

M12

M18

M30

Shielded

Shielded

Shielded

Unshielded

Shielded

Unshielded

Model

E2EM-X4X[]

E2EM-X8X[]

E2EM-X16MX[]

E2EM-X15X[]

E2EM-X30MX[]

ensing distance

4 mm ±10%

8 mm ±10%

16 mm ±10%

15 mm ±10%

30 mm ±10%

Set distance *1

0 to 3.2 mm

0 to 6.4 mm

0 to 12.8 mm

0 to 12 mm

0 to 24 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to 
Engineering Data on Data Sheet.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron, 18 × 18 × 1 mm

Iron, 45 × 45 × 1 mm

Iron, 30 × 30 × 1 mm

Iron, 70 × 70 × 1 mm

Response frequency *2

1 kHz

0.5 kHz

0.4 kHz

0.25 kHz

0.1 kHz

Power supply voltage 
(operating voltage range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Leakage current

0.8 mA max.

Control 
output

Load 
current

5 to 100 mA

Residual 
voltage *3

5 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

X1 Models: Operation indicator (red), Setting indicator (green) 
X2 Models: Operation indicator (red)

Operation mode 
(with sensing object 
approaching)

X1 Models: NO 
X2 Models: NC 
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67, in-house standards: oil-resistant

Connection method

Pre-wired Models (Standard cable length: 2 m)

Weight (packed state)

Approx. 60 g

Approx. 130 g

Approx. 150 g

Approx. 180 g

Approx. 210 g

Materials

Case

Nickel-plated brass

Sensing 
surface

PBT

Clamping 
nuts

Nickel-plated brass

Toothed 
washer

Zinc-plated iron

Accessories

Instruction manual

*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except X2 Models). 
*2. The response frequency is an average value. 
       Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, 
       and a set distance of half the sensing distance. 
*3. The residual voltage is 5 V. Make sure that the device connected to the Sensor can withstand the residual voltage. 
       (Refer to Data Sheet for details.)

E2EM-X[]C[] DC 3-Wire Models

Size

M8

M12

M18

M30

Shielded

Shielded

Shielded

Shielded

Shielded

Model

E2EM-X2C[](-M1)

E2EM-X4C[](-M1)

E2EM-X8C[](-M1)

E2EM-X15C[](-M1)

Sensing distance

2 mm ±10%

4 mm ±10%

8 mm ±10%

15 mm ±10%

Set distance

0 to 1.6 mm

0 to 3.2 mm

0 to 6.4 mm

0 to 12 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to 
Engineering Data on Data Sheet.)

Standard sensing object

Iron, 8 × 8 × 1 mm

Iron, 12 × 12 × 
1 mm

Iron, 18 × 18 × 
1 mm

Iron, 30 × 30 × 
1 mm

Response frequency *1

1.5 kHz

0.5 kHz

0.3 kHz

0.1 kHz

Power supply voltage 
(operating voltage range) 
*2

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Current consumption

13 mA max.

Control 
output

Load 
current *2

200 mA max.

Residual 
voltage

2 V max. (Load current: 200 mA, Cable length: 2 m)

Indicators

Operation indicator (yellow)

Operation mode 
(with sensing object 
approaching)

C1 Models: NO 
C2 Models: NC 
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Protection circuits

Reverse polarity protection, Load short-circuit protection, Surge suppressor

Ambient temperature 
range *1

Operating/Storage: -40 to 85°C (with no icing or condensation)

Operating: -25 to 70°C 
Storage: -40 to 85°C 
(with no icing or 
condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C in the temperature 
range of -40 to 85°C 
±10% max. of sensing distance at 23°C in the temperature 
range of -25 to 70°C

±15% max. of sensing 
distance at 23°C in the 
temperature range of 
-25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z 
directions

Shock resistance

Destruction: 500 m/s2 
10 times each in X, Y, 
and Z directions

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant 
Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m) 
Connector Models

Weight 
(packed 
state)

Pre-wired 
Models

Approx. 65 g

Approx. 75 g

Approx. 150 g

Approx. 195 g

Connector 
Models

Approx. 15 g

Approx. 25 g

Approx. 40 g

Approx. 90 g

Materials

Case

Stainless steel 
(SUS303)

Nickel-plated brass

Sensing 
surface

PBT

Clamping 
nuts

Nickel-plated brass

Toothed 
washer

Zinc-plated iron

Accessories

Instruction manual

*1. The response frequency is an average value. 
       Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, 
       and a set distance of half the sensing distance. 
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and 
       make sure that the Sensor has a control output of 100 mA maximum.

 

Tên sản phẩmCảm biến tiệm cận omron E2EM
Xuất xứ-
Bảo hành-
Chi tiết-

SẢN PHẨM LIÊN QUAN