Size | M12 | M18 | M30 |
| |
Shielded |
| ||||
E2EH-X3D[] | E2EH-X7D[] | E2EH-X12D[] |
| ||
Sensing distance | 3 mm | 7 mm | 12 mm |
| |
Set distance *1 | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 9.6 mm |
| |
Differential travel | 15% max. of sensing distance |
| |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.) | ||||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron 21 × 21 × 1 mm | Iron 36 × 36 × 1 mm |
| |
Response frequency *2 | 500 Hz | 300 Hz | 100 Hz |
| |
Power supply voltage | 12 to 24 VDC, ripple (p-p): 10% max. |
| |||
Leakage current | 0.8 mA max. |
| |||
Control | Load | 3 to 100 mA (however, 3 to 50 mA at 100 to 110 ° C) |
| ||
Residual | Polarity Models: 3 V max. |
| |||
Indicators | D1 Models: Operation indicator (red), Setting indicator (yellow) |
| |||
Operation mode (with | D1 Models: NO |
| |||
Protection circuits | Surge suppressor, Load short-circuit protection |
| |||
Ambient | Operating: 0 to 100 ° C (0 to 110 ° C 1,000 h) *4 |
| |||
Ambient humidity range | 35% to 95% |
| |||
Temperature influence | ± 10% max. of sensing distance at 23 ° C in the temperature range of 0 to 70 ° C. |
| |||
Voltage influence | ± 10% max. of sensing distance at rated voltage in the 15% rated voltage range. |
| |||
Insulation resistance | 50 M Ω min. (at 500 VDC) between current-carrying parts and case |
| |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case |
| |||
Vibration resistance | Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
| |||
Shock resistance | Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions |
| |||
Degree of protection | IEC IP67, DIN 40050-9 IP69K *5 |
| |||
Connection method | Pre-wired Models (Standard cable length 2 m), Connector Models |
| |||
Weight | Pre-wired | Approx. 80 g | Approx. 145 g | Approx. 220 g |
|
Connector | Approx. 30 g | Approx. 55 g | Approx. 125 g |
| |
Materials | Case, | Stainless steel (SUS316L) |
| ||
Sensing | PBT |
| |||
Cable | Heat-resistant PVC cable (Pre-wired model) |
| |||
Accessories | Instruction manual |
|
*1. Use the yellow indicator on D1 Models as a guide.
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object,
and a set distance of half the sensing distance.
*3. The residual voltage of each E2EH-X[]D[] DC 2-Wire Model is 5 V. When connecting to a device, make sure that the
device can withstand the residual voltage. (Refer to Data Sheet.)
*4. Operation with power supplied for 1,000 h has been verified at 110°C. Do not bend the cable repeatedly at 100°C or
higher.
*5. IP69K Degree of Protection Specification
IP69K is a protection standard against high temperature and high-pressure water defined in the German standard
DIN 40050, Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a
specified nozzle shape at a rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each
at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane.
E2EH-X[]C[]/B[] DC 3-Wire Models
Size | M12 | M18 | M30 | |
Shielded | ||||
E2EH-X3C[]/B[] | E2EH-X7C[]/B[] | E2EH-X12C[]/B[] | ||
Sensing distance | 3 mm±10% | 7 mm±10% | 12 mm±10% | |
Set distance *1 | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 9.6 mm | |
Differential travel | 15% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.) | |||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron 21 × 21 × 1 mm | Iron 36 × 36 × 1 mm | |
Response frequency *2 | 500 Hz | 300 Hz | 100 Hz | |
Power supply voltage | 12 to 24 VDC, ripple (p-p): 10% max. | |||
Current consumption | 10 mA max. | |||
Control | Load | 100 mA max. (however, 50 mA max. at 100 to 120 ° C) | ||
Residual | 2 V max. (Load current: 100 mA, Cable length 2 m) | |||
Indicators | Operation indicator (yellow) | |||
Operating mode | C1 Models: NO | |||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Load short-circuit protection, Reversed output polarity protection | |||
Ambient | Operating: 0 to 100 ° C (0 to 120 ° C 1,000 h) *2 | |||
Ambient humidity range | 35% to 95% | |||
Temperature influence | ± 10% max. of sensing distance at 23 ° C in the temperature range of 0 to 70 ° C. | |||
Voltage influence | 10% max. of sensing distance at rated voltage in the 15% rated voltage range. | |||
Insulation resistance | 50 M Ω min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | |||
Shock resistance | Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions | |||
Degree of protection | IEC IP67, DIN 40050-9 IP69K | |||
Connection method | Pre-wired Models (Standard cable length 2 m), Connector Models | |||
Weight | Pre-wired | Approx. 80 g | Approx. 145 g | Approx. 220 g |
Connector | Approx. 30 g | Approx. 55 g | Approx. 125 g | |
Materials | Case, | Stainless steel (SUS316L) | ||
Sensing | PBT | |||
Cable | Heat-resistant PVC cable (Pre-wired Model) | |||
Accessories | Instruction manual |
Tên sản phẩm | Cảm biến tiệm cận omron E2EH |
Xuất xứ | - |
Bảo hành | - |
Chi tiết | - |