Size | M8 | ||||
Sensing distance | Single | Double | |||
Type | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2B-S08[]S01 | E2B-S08[]N02 | E2B-S08[]S02 | E2B-S08[]N04 | |
Sensing distance | 1.5 mm ± 10% | 2 mm ± 10% | 2 mm ± 10% | 4 mm ± 10% | |
Setting distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 1.6 mm | 0 to 3.2 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal.) | ||||
Standard sensing object | 8 × 8 × 1 mm | 8 × 8 × 1 mm | 8 × 8 × 1 mm | 12 × 12 × 1 mm | |
Response frequency *1 | 2,000 Hz | 1,000 Hz | 1,500 Hz | 1,000 Hz | |
Power supply voltage | 10 to 30 VDC. (including 10% ripple (p-p)) | ||||
Current consumption | 10 mA max. | ||||
Output type | -B models: PNP open collector | ||||
Control | Load current *2 | 200 mA max. (30 VDC max.) | |||
Residual voltage | 2 V max. (under load current of 200 mA with cable length of 2 m) | ||||
Indicator | Operation indicator (Yellow LED) | ||||
Operation mode (with sensing | -B1/-C1 models: NO | ||||
Protection circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, | ||||
Ambient air temperature | Operation and storage: -25 to 70°C (with no icing or condensation) | ||||
Temperature influence *2 | ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C | ||||
Ambient humidity | Operation and Storage: 35 to 95% | ||||
Voltage influence | ±1% max. of sensing distance in 24 VDC ±15% | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | 500 m/s2 , 10 times each in X, Y and Z directions | ||||
Standard and listings | (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) | ||||
Connecting method | Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). | ||||
Weight | Pre-wired model | Short body: Approx. 65 g, Long body: Approx. 65 g | |||
Connector model | Short body: Approx. 20 g, Long body: Approx. 20 g | ||||
Material | Case | Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).) | |||
Sensing surface | PBT | ||||
Cable | Standard cable is 4 mm dia. PVC. | ||||
Clamping nut | Brass-nickel plated | ||||
Toothed washer | Zinc-plated iron |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing
distance.
*2. When using any model of M8 size at an ambient temperature between -25°C and 60°C, use a load current of 200 mA
max., at an ambient temperature between 60°C and 70°C, use a load current of 100 mA max.
Size | M12 | ||||
Sensing distance | Single | Double | |||
Type | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2B-M12[]S02 | E2B-M12[]N05 | E2B-M12[]S04 | E2B-M12[]N08 | |
Sensing distance | 2 mm ± 10% | 5 mm ± 10% | 4 mm ± 10% | 8 mm ± 10% | |
Setting distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 3.2 mm | 0 to 6.4 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal.) | ||||
Standard sensing object | 12 × 12 × 1 mm | 15 × 15 × 1 mm | 12 × 12 × 1 mm | 24 × 24 × 1 mm | |
Response frequency *1 | 1,500 Hz | 800 Hz | 1,000 Hz | 800 Hz | |
Power supply voltage | 10 to 30 VDC. (including 10% ripple (p-p)) | ||||
Current consumption | 10 mA max. | ||||
Output type | -B models: PNP open collector | ||||
Control | Load current | 200 mA max. (30 VDC max.) | |||
Residual voltage | 2 V max. (under load current of 200 mA with cable length of 2 m) | ||||
Indicator | Operation indicator (Yellow LED) | ||||
Operation mode (with sensing | -B1/-C1 models: NO | ||||
Protection circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, | ||||
Ambient air temperature | Operation and storage: -25 to 70°C (with no icing or condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C | ||||
Ambient humidity | Operation and Storage: 35 to 95% | ||||
Voltage influence | ±1% max. of sensing distance in 24 VDC ±15% | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | 1,000 m/s2 , 10 times each in X, Y and Z directions | ||||
Standard and listings | (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) | ||||
Connecting method | Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). | ||||
Weight | Pre-wired model | Short body: Approx. 75 g, Long body: Approx. 80 g *2 | |||
Connector model | Short body: Approx. 35 g, Long body: Approx. 40 g | ||||
Material | Case | Brass-nickel plated | |||
Sensing surface | PBT | ||||
Cable | Standard cable is 4 mm dia. PVC. | ||||
Clamping nut | Brass-nickel plated | ||||
Toothed washer | Zinc-plated iron |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing
distance.
*2. In case of ‘WP’ cable type.
Size | M18 | ||||
Sensing distance | Single | Double | |||
Type | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2B-M18[]S05 | E2B-M18[]N10 | E2B-M18[]S08 | E2B-M18[]N16 | |
Sensing distance | 5 mm ± 10% | 10 mm ± 10% | 8 mm ± 10% | 16 mm ± 10% | |
Setting distance | 0 to 4 mm | 0 to 8 mm | 0 to 6.4 mm | 0 to 12.8 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal.) | ||||
Standard sensing object | 18 × 18 × 1 mm | 30 × 30 × 1 mm | 24 × 24 × 1 mm | 48 × 48 × 1 mm | |
Response frequency *1 | 600 Hz | 400 Hz | 500 Hz | 400 Hz | |
Power supply voltage | 10 to 30 VDC. (including 10% ripple (p-p)) | ||||
Current consumption | 10 mA max. | ||||
Output type | -B models: PNP open collector | ||||
Control | Load current | 200 mA max. (30 VDC max.) | |||
Residual voltage | 2 V max. (under load current of 200 mA with cable length of 2 m) | ||||
Indicator | Operation indicator (Yellow LED) | ||||
Operation mode (with sensing | -B1/-C1 models: NO | ||||
Protection circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, | ||||
Ambient air temperature | Operation and storage: -25 to 70°C (with no icing or condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C | ||||
Ambient humidity | Operation and Storage: 35 to 95% | ||||
Voltage influence | ±1% max. of sensing distance in 24 VDC ±15% | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | 1,000 m/s2 , 10 times each in X, Y and Z directions | ||||
Standard and listings | (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) | ||||
Connecting method | Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). | ||||
Weight | Pre-wired model | Short body: Approx. 95 g, Long body: Approx. 110 g *2 | |||
Connector model | Short body: Approx. 60 g, Long body: Approx. 80 g | ||||
Material | Case | Brass-nickel plated | |||
Sensing surface | PBT | ||||
Cable | Standard cable is 4 mm dia. PVC. | ||||
Clamping nut | Brass-nickel plated | ||||
Toothed washer | Zinc-plated iron |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing
distance.
*2. In case of ‘WP’ cable type.
Size | M30 | ||||
Sensing distance | Single | Double | |||
Type | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2B-M30[]S10 | E2B-M30[]N20 | E2B-M30[]S15 | E2B-M30[]N30 | |
Sensing distance | 10 mm ± 10% | 20 mm ± 10% | 15 mm ± 10% | 30 mm ± 10% | |
Setting distance | 0 to 8 mm | 0 to 16 mm | 0 to 11.25 mm | 0 to 22.5 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal.) | ||||
Standard sensing object | 30 × 30 × 1 mm | 60 × 60 × 1 mm | 45 × 45 × 1 mm | 90 × 90 × 1 mm | |
Response frequency *1 | 400 Hz | 100 Hz | 250 Hz | 100 Hz | |
Power supply voltage | 10 to 30 VDC. (including 10% ripple (p-p)) | ||||
Current consumption | 10 mA max. | ||||
Output type | -B models: PNP open collector | ||||
Control | Load current | 200 mA max. (30 VDC max.) | |||
Residual voltage | 2 V max. (under load current of 200 mA with cable length of 2 m) | ||||
Indicator | Operation indicator (Yellow LED) | ||||
Operation mode (with sensing | -B1/-C1 models: NO | ||||
Protection circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, | ||||
Ambient air temperature | Operation and storage: -25 to 70°C (with no icing or condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C | ||||
Ambient humidity | Operation and Storage: 35 to 95% | ||||
Voltage influence | ±1% max. of sensing distance in 24 VDC ±15% | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | 1,000 m/s2 , 10 times each in X, Y and Z directions | ||||
Standard and listings | (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) | ||||
Connecting method | Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). | ||||
Weight | Pre-wired model | Short body: Approx. 160 g, Long body: Approx. 210 g *2 | |||
Connector model | Short body: Approx. 140 g, Long body: Approx. 160 g | ||||
Material | Case | Brass-nickel plated | |||
Sensing surface | PBT | ||||
Cable | Standard cable is 4 mm dia. PVC. | ||||
Clamping nut | Brass-nickel plated | ||||
Toothed washer | Zinc-plated iron |
Tên sản phẩm | Cảm biến tiệm cận omron E2B |
Xuất xứ | - |
Bảo hành | - |
Chi tiết | - |